Bug #5938
closedError in the buildcfg
0%
Description
I change the data-base, and I am getting this on the new buildcfg. I dont know if it is due to a base error or something else.
psa-tests@scgw2:~$ buildcfg --tm 01B 04[BC] 05[ABC] 07[ABC] 12[AB] 13[ABC] 14[BC] FRS
-> Filling crystals structure
-> Filling carrier structure
-> Filling mezzanine segment structure
Traceback (most recent call last):
File "/home/psa-tests/bin/buildcfg", line 76, in <module>
mezzanines=cfg.get_mezzanine_by_carriers(v_carriers)
File "/home/carrier/carrierLSC_HG/agataconfiguration.py", line 255, in get_mezzanine_by_carriers
result.extend (tm_get_mezzanine_by_carrier(carriers[i][1][:11]))
TypeError: 'NoneType' object is unsubscriptable
Updated by Ralet Damian almost 11 years ago
- Status changed from New to Closed
- Priority changed from Urgent to Normal
Problem seems solved. It was comming from a data-base error.
Updated by Legay Eric almost 11 years ago
- Status changed from Closed to Feedback
- Assigned To changed from Legay Eric to Ralet Damian
And what was this mistake ?
Just to know
Updated by Ralet Damian almost 11 years ago
- Status changed from Feedback to Closed
- Assigned To changed from Ralet Damian to Legay Eric
There were two time a master carrier assigned to a crystal.